AJAY DRAINLINE SOLVENTFIT (SF) JOIINTING SYSTEM

INSTALLATIN GUIDLELINES

  • Cut pipe straight. Inspect the pipe end thoroughly after cutting & ensue that there is no crack at the mouth portions of the pipe. If crack noticed cut off a min. 25mm beyond the visible crack before proceeding.
  • Chamfer the spigot end of pipe to 15 degrees and remove all burrs. Burrs will score the channel & obstruct the flow water discharge.
  • Use a clean & dry cloth to wipe the dirt, rain water & moisture on the surface of the pipe. Also clean the dirt from inside the socket portion of the fitting.
  • Check dry fitment of the pipe. It should easily go 2/3 of the socket portion of the fitting.
  • Apply thin coat of Ajay Drainline regular-bodied solver cement into the fitting socket & on the spigot end of the pipe. Do not puddle cement in the socket.
  • Insert pipe into the socket immediately and rotate 90 degree while it is in wet condition. Make sure pipe goes all the way to the bottom the fitting.
  • Hold pipe and fittings together (30 sec approx.) to make sure pipe does not push out.
  • Wipe of excess cement with clean & dry cloth & allow it for curing.

Ajay Drainline PVC Solvent Cement

Ajay Drainline Solvent (SF) pipes & fittings are joined with Ajay Drailine solvent cement. For faster plumbing and leak proof joints we recommend the use of Ajay Drainline solvent cement only.

AJAY UV-R PRESSURE PIPES AND FITTINGS

Ajay UPVC Pressure Pipes and fittings are manufactured from virgin UV stabilised high strength PVC Compound. These pipes are pre-socketed are joined using solvent cement.